4. Installation
PNEG-1283 Moisture Sampler 9
10. Now put the Moisture Sampler assembly up to the discharge box again and put in the 5/16" bolts
and nuts and tighten just enough to firmly hold Moisture Sampler in place. Use a marker and mark
the four (4) holes at the sensor end of the assembly as shown in Figure 4E. Also mark the square
hole inside the sample tube as shown in Figure 4E.
Figure 4E
11. Remove the Moisture Sampler again and drill the four (4) bolt holes at the sensor end with a 3/8"
drill bit and cut out the square hole marked out in Step 10.
Mark and drill holes with a
5/16" drill bit
Mark and cut square hole
Vue de la page 8