135 Ft Diameter Bin — AlphaModels:40–SERIES BINConstruction ManualPNEG-4135ADate: 10-14-13PNEG-4135A
Chapter 1: Safety PrecautionsTable 1-1 Description of the different cautionary symbols (cont'd.)Symbol DescriptionThis symbol indicates a potenti
Chapter 7: Roof AssemblyAssembling Purlin Number 6Purlin number 6 is located sixth from the eave.Before You BeginPlace two roof rafters on the ground
Chapter 7: Roof AssemblyFigure 7-18 Purlin location 6A Left-hand lower roof rafter (CTR-0549 andCTR-0635)H Purlin (CTR-0559)B1/2 x 1-3/4 in. flange bo
Chapter 7: Roof AssemblyAssembling Purlin Number 5Purlin number 5 is located fifth from the eave.Before You BeginPlace two roof rafters on the ground
Chapter 7: Roof AssemblyFigure 7-19 Purlin location 5A Left-hand lower roof rafter (CTR-0549and CTR-0635)H Purlin (CTR-0558)B1/2 x 1-3/4 in. flange bo
Chapter 7: Roof AssemblyAssembling Purlin Number 4Purlin number 4 is located fourth from the eave.Before You BeginPlace two roof rafters on the ground
Chapter 7: Roof AssemblyFigure 7-20 Purlin location 4A Left-hand lower roof rafter (CTR-0549and CTR-0635)H Purlin (CTR-0557)B1/2 x 1-3/4 in. flange bo
Chapter 7: Roof AssemblyAssembling Purlin Number 3Purlin number 3 is located second from the eave.Before You BeginPlace two roof rafters on the ground
Chapter 7: Roof AssemblyFigure 7-21 Purlin location 3A Left-hand lower roof rafter (CTR-0549and CTR-0635)H Purlin (CTR-0556)B1/2 x 1-3/4 in. flange bo
Chapter 7: Roof AssemblyAssembling Purlin Number 2Purlin number 2 is located second to the eave.Before You BeginPlace two roof rafters on the ground w
Chapter 7: Roof AssemblyFigure 7-22 Purlin location 2A Left-hand lower roof rafter (CTR-0549and CTR-0635)H Purlin (CTR-0555)B1/2 x 1-3/4 in. flange bo
Chapter 1: Safety PrecautionsATTENTION: Decal shown below must be present on the outside of the door cover of the two ring, 24 in.(61 cm) porthole doo
Chapter 7: Roof AssemblyAssembling Purlin Number 1Purlin number 1 is located closest to the eave.Before You BeginPlace two roof rafters on the ground
Chapter 7: Roof AssemblyFigure 7-23 Purlin location 1A Left-hand lower roof rafter (CTR-0549and CTR-0635)H Purlin (CTR-0554)B1/2 x 1-3/4 in. flange bo
Chapter 7: Roof AssemblyAssembling a Double A-FrameTo achieve the required spacing between each A-frame, a double A-frame will need to be assembled pr
Chapter 7: Roof AssemblyFigure 7-25 Double A-frame assembly exploded viewARoof rafter (CTR-0548 and CTR-0549)F1/2 x 1-3/4 in. flange bolt (S-10252)BLe
Chapter 7: Roof AssemblyAssembling Center Collar Channels and Cap PlatesThe following procedure is for assembling the center collar channels and cap p
Chapter 7: Roof Assembly8. Install the short center collar channels (F) to the third set of holes located on each long center collarchannel (I).9. Ins
Chapter 7: Roof AssemblyFigure 7-28 Assembling the short center collar channels to the long center collar channelC 1/2 x 1-3/4 in. flange bolt (S-1025
Chapter 7: Roof AssemblyFigure 7-29 Assembling the short center collar channels to the long center collar channelC 1/2 x 1-3/4 in. flange bolt (S-1025
Chapter 7: Roof AssemblyFigure 7-30 Assembling the center cap platesA3/8 in. nut (S-456)N Tube caulkICenter collar channel assembly O Splice plate (CT
Chapter 7: Roof AssemblyFigure 7-31 Assembly of side cap platesA3/8 in. nut (S-456) Q Side cap plate (CTR-0360), approximately 145lb (65.77 kg)LCenter
Chapter 1: Safety PrecautionsATTENTION: Decal shown below must be present on the outside of the door cover of the two ring, 24 in.(61 cm) porthole doo
Chapter 7: Roof AssemblyNOTE: Eyebolt will pass through three layers of steel: the splice plate (V), the center cap plates (Land M), and the long cent
Chapter 7: Roof AssemblyDetermine the correct orientation of the center collar in relation to any stairs or conveyor systems. Eachpiece of the center
Chapter 7: Roof Assembly6. Secure with flange bolts (L) and flange nuts (J).7. Locate the column of three holes (K) that are not paired together on th
Chapter 7: Roof Assembly10.Loosely tighten all of the hardware allowing the center collar pieces to be adjusted for alignment afterthe center collar c
Chapter 7: Roof AssemblyFigure 7-35 Assembling the center collar channels and cap plates assemblyQ Appropriate lifting chains S Cap plate assembly, ap
Chapter 7: Roof AssemblyCenter Collar PlacementThe following figure gives the approximate height needed to install the center collar.With two sidewall
Chapter 7: Roof AssemblyIMPORTANT: The ladder assembly (A or B or C or D) and the manway hole (I or J or K or L) locationsmust be determined before th
Chapter 7: Roof AssemblyGuidelines for Assembling and Lifting the A-Frame Rafter SectionsThe roof is assembled in sections and referred to as A-frame
Chapter 7: Roof AssemblyFigure 7-39 Recommended lifting points for a Double A-frame sectionA Purlin clipThe A-frame rafter section has two configurati
Chapter 7: Roof AssemblyTable 7-3 For alpha roofBin DiameterPeak Capacity Roof Snow LoadApproximate A-Frame Weight135 ft. (41.15 m) 50 K 30 PSF 2726 l
Chapter 1: Safety PrecautionsSafety Sign-off SheetSign-off sheet verifying that all personnel have read and understood the safety instructions.As a re
Chapter 7: Roof AssemblyAA-frame rafter assembly C 1/2 x 1-3/4 in. flange bolt (S-10252)BCenter collar (CTR-0347)D1/2 in. flange nut (S-10253)Attachin
Chapter 7: Roof AssemblyAssembling the Roof Panel ClipsThe roof panel clips are located at the top of the roof rafters nearest to the center collar ra
Chapter 7: Roof AssemblyALeft-hand roof rafter (CTR-0548 and CTR-0549)D1/2 x 1-3/4 in. flange bolt (S-10252)BRoof panel clip (CTR-0346)E1/2 in. flange
Chapter 7: Roof AssemblyInstalling the 6–Hole Intermediate PurlinsIntermediate purlins must be installed to connect each A-frame roof rafter assembly
Chapter 7: Roof AssemblyAttaching the Roof PanelsRoof panels overlap the previous roof panel, giving protection from outside elements.Before You Begin
Chapter 7: Roof AssemblyALower roof panel (CTR-0344)E5/16 in. flange nut (S-3611)D5/16-18 x 1 flange bolt with sealing washer(S-10260)G Roof rafter3.
Chapter 7: Roof Assembly7. After installing all the lower roof panels onto the roof, with assistance, position an middle roof panel(D) onto a A-frame
Chapter 7: Roof AssemblyFigure 7-47 Installing the middle roof panelsALower roof panel (CTR-0344)F5/16 in. flange nut (S-3611)DMiddle roof panel (CTR-
Chapter 7: Roof AssemblyFigure 7-48 Installing the first upper roof panelC Upper roof panel (CTR-0337)E5/16-18 x 1 flange bolt with sealing washer (S-
Chapter 7: Roof AssemblyFigure 7-49 Installing the middle roof panelsC Upper roof panel (CTR-0337) F 5/16 in. flange nut (S-3611)D Middle roof panel (
NOTES14 Pneg-4135A 135 Ft Diameter 40-Series Bin
Chapter 7: Roof Assembly22.Field drill holes (C) into the roof panels (A) through holes in the top flange of the rafters (E). Fastenthe panels and the
Chapter 7: Roof AssemblyC Roof panel holes (drilled through rafter) G Roof panel holes (drilled through rafter clip)D PurlinInstalling the Roof Flashi
Chapter 7: Roof Assembly6. Install flange bolts (B) and flange nuts (C), securing the roof flashing section (A) to the roof panel ribs.7. Continue ins
Chapter 7: Roof AssemblyInstalling Center Collar Channels and Cap Plates AssemblyThe following procedure is for installing the center collar channels
Chapter 7: Roof AssemblyFigure 7-52 Lifting the center collar channel and cap platesA Tube caulk D Cap plate assembly, approximately 1700 lb(771.1 kg)
Chapter 7: Roof AssemblyFigure 7-53 Cap plate assembly installedG 3/8 x 1 in. bolt with sealing washer (S-7487)IHoles for conveyor support bracketsH3/
Chapter 7: Roof AssemblyFigure 7-54 Conveyor support bracketsA3/8 x 1-1/2 in. flange bolt (S-7488) C 3/8 in. flange nut (S-456)BConveyor support brack
8 AccessoriesTopics Covered in this Chapter▪ Installing Roof Ladder Steps▪ Roof Ring Placement▪ Installing a Roof Ring▪ Installation of Peak–To– Exhau
Chapter 8: AccessoriesInstalling Roof Ladder StepsRoof ladder steps will allow access to roof and manway access.What You Should KnowEach eave-to-peak
Chapter 8: AccessoriesUse the following table as a guide to the location of each ladder step (rung).Table 8-1 Ladder Rung Placement ChartBin DiameterL
2 General OverviewTopics Covered in this Chapter▪ General Information▪ Anchor Bolt Charts▪ Tools Required for Construction▪ Guidelines for Proper Stor
Chapter 8: AccessoriesNOTE: The table above shows the correct ladder step and part number to be installed in the correspondinghole in the roof rib. Sh
Chapter 8: AccessoriesInstalling a Roof RingQuantity and part numbers of roof ring kits vary with the location placement and with the size of each bin
Chapter 8: Accessories6. Install the threaded stud (F) with stud nuts (G) to the end of the roof ring section (B).NOTE: Install the threaded stud (F)
Chapter 8: AccessoriesInstallation of Peak–To– Exhauster Ladder KitBefore installing the roof exhauster, the peak-to-exhauster ladder kit may be insta
Chapter 8: AccessoriesTable 8-2 Peak-to-Exhauster Ladder Rung KitBin DiameterLocation 72 ft 75 ft 78 ft 90 ft 105 ft 135 ft↑Bin Peak37 LS-260-136 LS-2
Chapter 8: Accessories1. Position the roof panels (K) spanned by the roof exhauster mounting plate on the ground. Align theroof panel holes as if they
Chapter 8: Accessories5. Remove the roof exhauster mounting plate (F), to make the necessary cut along the mark or scribe(I).Figure 8-7 Using the roof
Chapter 8: AccessoriesFigure 8-8 Roof exhauster assemblyA5/16 x 1 in. hex bolt (S-10260)D5/16 in. flange nut, (S-3611)BRoof exhauster hoodEExhauster m
Chapter 8: AccessoriesNOTE: The roof exhauster kit is shipped with additional parts. The following part numbers will not be usedon 40-series bins:MIS-
Chapter 8: AccessoriesFigure 8-9 Installing roof exhausterARoof exhauster flashing (CTR-0347)E5/16 flange nut (S-3611)B5/16-18 x 1 flange bolt, with s
Chapter 2: General OverviewFigure 2-1 Anchor bolt chords for 135 diameter 3–post binBolt Radius (B)Anchor Quantityft and inm67 – 6-1/2 20.587 13516 Pn
Chapter 8: AccessoriesFigure 8-10 Sealing caulk locationDRoof exhauster assemblyHSealing caulkAssembling the Auto Roof VentThe following instructions
Chapter 8: AccessoriesFigure 8-11 Assembling the flapAHold-down angle (MIS-4404)DRoof vent housing assembly (MIS-6778)B5/16 x 1-1/4 in hex bolt (S-277
Chapter 8: Accessories5. Insert another hex bolt (B) through the other side of the roof vent housing (D), and install a flange nut(E) to the hex bolt
Chapter 8: AccessoriesInstalling the Wire Grill Guard and Auto Roof VentsThe following instructions are for installing the wire grill guard roof vent
Chapter 8: AccessoriesC Foam strips (side strips MIS-6781) (topstrip MIS-6780)G 5/16 x 3/4 in. flange bolt (S-275)DRoof panel (part number varies)H5/1
Chapter 8: AccessoriesFigure 8-14 Manway coverAHinge base (MW-291) GManway sillBManway roof panel (CTR-0302)HHinge leaf (MW-272)C 5/16 x 3/4 in. hex b
Chapter 8: AccessoriesNOTE: A portion of the last ladder section may need to be cut to fit the proper length to the ground or tothe intermediate platf
Chapter 8: AccessoriesFigure 8-16 Positioning the ladderA Manway access B Ladder assembly1. Install the right-hand starter bracket (C) to the top hole
Chapter 8: Accessories7. Tighten hardware to the recommended torque specifications. See Bolt Torque Specifications, page26.8. Install the ladder (B) t
Chapter 8: AccessoriesFigure 8-17 Installing ladder bracketsB Ladder assembly J5/16 in. hex bolt (S-275)C Starter bracket (RH LDR-4347)KStarter bracke
Chapter 2: General OverviewChord (A)Lengthft and inm1 3 – 1-3/4 0.9592 6 – 3-7/16 1.9163 9 – 5-1/8. 2.8734 12 – 6-11/16 3.827515 – 8-1/4 4.7826 18 – 9
Chapter 8: AccessoriesInstalling Inside Ladder Bottom BracketThe ladder bottom bracket keeps the lower portion of the ladder secure.What You Should Kn
Chapter 8: AccessoriesFigure 8-18 Bottom ladder bracketA Ladder assembly E5/16 x 3/4 in. flange bolt (S-7482)BLadder bottom bracket (LDR5133)F3/8 in.
Chapter 8: Accessories• Installation of multiple systems may require additional wind rings and must be placed a minimum of90 degrees apart. Installati
Chapter 8: AccessoriesFigure 8-19 Two and three post stiffener examplesATypical 24-ring binDTwo post stiffenerBTypical 29-ring binEThree post stiffene
Chapter 8: AccessoriesTable 8-3 Sidewall Instructions (Two Post Stiffener)Number of Rings on the Bin Chute Location Horizontal Starting LocationAllLoc
Chapter 8: AccessoriesFigure 8-20 First Chute Locations (Two Post Stiffener Only) and Spacing of each baffle chuteAStiffener’s center line G Field dri
Chapter 8: AccessoriesNOTE: Depending on the location of the baffle chute (C), the measurement from the sidewall edgewill vary (D or E).3. Locate the
Chapter 8: AccessoriesEMeasurement from edge of sidewall sheetto center line of baffle chute, 75 in. (190.5cm)KTypical spacing, approximately 8 in. (2
Chapter 8: AccessoriesFigure 8-22 Vertical line location of discharge chuteAColumn of bolt holes C Measurement, approximately 11 in. (27.94 cm)BBaffle
Chapter 8: AccessoriesFigure 8-23 Horizontal line location of discharge chuteD Vertical center line F Center of discharge chute locationE Sidewall hor
Chapter 2: General OverviewTools Required for ConstructionGeneral tools needed to perform this construction• Combination wrench set 7/16 in. to 1 in.•
Chapter 8: AccessoriesFigure 8-24 Discharge Chute Hole OutlineD Vertical center line G Horizontal center line10.Separate the upper sidewall panel (I)
Chapter 8: AccessoriesFigure 8-25 Discharge chute assembly (view form inside the bin)H Discharge chute assembly J Lower sidewall panelI Upper sidewall
Chapter 8: AccessoriesFigure 8-26 Field drilling discharge chute assembly (view from inside the bin)H Discharge chute assembly K 3/8 x 1-1/2 in. flang
Chapter 8: AccessoriesFigure 8-27 Reinstall baffle chute (view from inside the bin)BBaffle chuteM Field drilled hole location15.Tighten hardware to th
Chapter 8: AccessoriesWind Ring RequirementsWind rings give additional strength against high winds and uneven loads. The quantities and placement ofwi
Chapter 8: AccessoriesFigure 8-29 Dimensions for OSHA Compliant Ladder Rung PlacementNOTE: Ensure the wind rings are installed in rela-tion to the lad
Chapter 8: Accessories1. Install a wind ring bracket (B) to each stiffener (C) using flange bolts (A) and flange nuts (D).Figure 8-30 Wind ring bracke
Chapter 8: AccessoriesFigure 8-31 Exploded view of wind ring installed at upper portion of stiffenerAFlange bolt with sealing washer (partnumber will
Chapter 8: AccessoriesFigure 8-32 Weather Cover AssemblyA Universal weather cover plate (CHT-1351)D 5/16 in. flange nut (S-3611)B1/4 in. self-drilling
GSI Group, LLC Limited WarrantyGSI Group, LLC Limited WarrantyThe GSI Group, LLC (“GSI”) warrants products which it manufactures to be free of defects
Chapter 2: General OverviewOverview for a Typical Bin InstallationThese are the typical steps one would perform when constructing a grain bin. Procedu
This equipment shall be installed in accordance with thecurrent installation codes and applicable regulationswhich should be carefully followed in all
All information, illustrations, photos, and specifications in this manual are based on the latestinformation available at the time of publication. The
Chapter 2: General OverviewGuidelines for Construction Procedures and Lifting Jack UsageThe following procedure is a guideline when using the required
Chapter 2: General OverviewGuidelines for Placement of the Decal Sidewall SheetUse the following as a general guideline the proper decal sheet placeme
Chapter 2: General OverviewFigure 2-3 Sample Gauge Sheet for a 3-Post 135 Diameter Bin22 Pneg-4135A 135 Ft Diameter 40-Series Bin
Chapter 2: General OverviewPneg-4135A 135 Ft Diameter 40-Series Bin 23
NOTES24 Pneg-4135A 135 Ft Diameter 40-Series Bin
3 Hardware RequirementsTopics Covered in this Chapter▪ Bolt and Nut Pairings▪ Hardware for 3–Post Sidewall Sheets on Bins that are 135 Ft in Diameter▪
Chapter 3: Hardware RequirementsTable 3-1 Hardware for 3-Post Sidewall Sheets on Bins that are 135 Ft in Diameter (cont'd.)GaugeHorizontal Seam V
Chapter 3: Hardware RequirementsIdentifying Bolt GradesBolts are identified by grade (or hardness), the grade can be identified by the markings on the
Chapter 3: Hardware RequirementsColor Chart for Bin Hardware Bucket LidsFor ease of identification, hardware is separated and identified by buckets wi
Chapter 3: Hardware RequirementsBolt IdentificationUse the following information to identify the bolts and where each must be used during installation
Table of ContentsContentsChapter 1 Safety Precautions ...
Chapter 3: Hardware RequirementsBolt S-7485An S–7485 is a 3/8 x 1 in. JS hex bolt with flanged head and without a sealing washer.Bolt (S-7485) is used
Chapter 3: Hardware RequirementsBolt S-7488An S–7488 is a 3/8 x 1 1/2 in. JS bolt that is pre-assembled with a sealing washer.Bolt (S-7488) is used in
Chapter 3: Hardware RequirementsBolt S-10165An S–10165 is a 3/8 x 2 in. JS bolt that is pre-assembled with a sealing washer.Bolt (S-10165) is used in
Chapter 3: Hardware RequirementsBolt S-10261An S–10261 is a 7/16 x 3 1/4 in. JS bolt that is pre-assembled with a sealing washer.Bolt (S-10261) is use
NOTES34 Pneg-4135A 135 Ft Diameter 40-Series Bin
4 Assembling Sidewall SheetsTopics Covered in this Chapter▪ Color Codes for Sidewall Gauge Identification▪ Orientation Detail for Top Sidewall Sheets▪
Chapter 4: Assembling Sidewall SheetsTable 4-2 Stripe Colors for Special Sidewall Characteristics (cont'd.)Extra Stripe ColorsType of Sidewall St
Chapter 4: Assembling Sidewall SheetsFigure 4-2 Standard and quad punched sidewall sheets as viewed from the outsideAVertical strip of caulkB10 in. (2
Chapter 4: Assembling Sidewall SheetsFigure 4-3 Caulking detail as viewed from inside of the binC 10 in. (25.4 cm) Strip of caulkD10 in. (25.4 cm) Str
Chapter 4: Assembling Sidewall SheetsCaulking Detail for Laminated Quad Pattern SheetsTo keep out moisture from overlapping the sheets, it is necessar
Table of ContentsClose-Punch Connection for a One-Ring Top Stiffener (16 Ga) and a Two-Ring Stiffener (16Ga) ...
Chapter 4: Assembling Sidewall SheetsFigure 4-5 Laminated figurate punched sidewall sheets view from outside of the binAStrip of caulkingB12 in. (30.4
Chapter 4: Assembling Sidewall Sheets• When assembling two assembled laminated sheets to each other, apply a strip of caulk (A) near theoutside edge o
NOTES42 Pneg-4135A 135 Ft Diameter 40-Series Bin
5 Base Angle InstallationTopics Covered in this Chapter▪ Installing the Base Angle▪ Anchor Bolt Detail▪ Installing the Base Angle Shims▪ Anchor Bolt W
Chapter 5: Base Angle InstallationFigure 5-1 Exploded view of base angle (view from inside the bin)A Final ring assembly D3/8 in. nut (S-9426)BBase an
Chapter 5: Base Angle InstallationAnchor Bolt DetailThe following is the minimum requirement for anchorage on standard tanks. Refer to sidedraw instru
Chapter 5: Base Angle InstallationInstalling the Base Angle ShimsA section of the base boot plate will rest on top of the base angle, therefore causin
Chapter 5: Base Angle InstallationAnchor Bolt Washer InstallationAnchor bolt washers help to cover the oversized hole in the base plate.Before You Beg
NOTES48 Pneg-4135A 135 Ft Diameter 40-Series Bin
6 StiffenersTopics Covered in this Chapter▪ Stiffener Part Number Description▪ Color Codes for Stiffener Gauge Identification▪ Outside Stiffened Lamin
Table of ContentsAttaching the A-Frames to the Center Collar ... 129Attachi
Chapter 6: StiffenersStiffener Part Number DescriptionPart numbers are printed on the end of each stiffener with the last two numbers designating the
Chapter 6: StiffenersOutside Stiffened Laminated Stiffener to Sidewall (10 GaugeLaminated and Thicker Only)Use the following information to attach the
Chapter 6: StiffenersStandard StiffenersUse the following information to determine the differences between the types of standard two-ringstiffeners.Fi
Chapter 6: StiffenersTop StiffenersUse the following information to determine the differences between the three types of top stiffeners.Figure 6-3 Ima
Chapter 6: StiffenersStiffeners SpliceUse the following information to determine the gauge of the splice needed to connect the stiffeners.Figure 6-4 S
Chapter 6: StiffenersBase StiffenersUse the following information to determine the differences between the base stiffeners.Figure 6-5 Images of the ba
Chapter 6: StiffenersBase BootsUse the following information to determine the differences between the base boots.Figure 6-6 Images of the base bootsCa
Chapter 6: StiffenersClose-Punch Connection for a One-Ring Top Stiffener (16 Ga) and aTwo-Ring Stiffener (16 Ga)Reference the following information fo
Chapter 6: StiffenersClose-Punch Connection for a Two-Ring Top Stiffener to a Two-RingStiffener (16 Ga)Reference the following information for a close
Chapter 6: StiffenersClose-Punch Connection for a Two-Ring Stiffener (16 Ga) to aTwo-Ring Stiffener (16 Ga)Reference the following information for a c
NOTES6 Pneg-4135A 135 Ft Diameter 40-Series Bin
Chapter 6: StiffenersClose-Punch Connection for a Two-Ring Stiffener (0–14 Ga) to aTwo-Ring Stiffener (0–14 Ga)Reference the following information for
Chapter 6: StiffenersClose-Punch Connection for a Two-Ring Stiffener (0–14 Ga) to aBase Stiffener (2–8 Ga)Reference the following information when con
Chapter 6: StiffenersTwo-Ring Stiffener (2–14 Ga) to a Base Stiffener (10–16 Ga)ConnectionReference the following information for a close-punch connec
Chapter 6: StiffenersClose-Punch Connection for a Two-Ring Stiffener (16 Ga) to a BaseStiffener (10–16 Ga)Reference the following information for a cl
Chapter 6: StiffenersClose-Punch Two-Ring Stiffener (2–14 Ga) to a Laminated Stiffener(2 Ga) with an Insert (10–14 Ga)Reference the following informat
Chapter 6: StiffenersClose-Punch Laminated Stiffener (2 Ga) with an Insert (10–14 Ga) toa Laminated Base Stiffener (2–5 Ga) with a Base Insert (2–14 G
Chapter 6: StiffenersBase Stiffener (10–16 Ga) to a Base Boot ConnectionReference the following information when connecting a base stiffener (CTS-2123
Chapter 6: StiffenersClose-Punch Connection for a Base Stiffener (2+2 Ga – 8 Ga) to aBase BootReference the following information for a close-punch co
Chapter 6: StiffenersClose-Punch Laminated Base Stiffener (2 Ga) with Insert(2+14 to 2+10 Ga) to a Base BootReference the following information when c
Chapter 6: Stiffeners12–Bolt Pattern Close-Punch Laminated Stiffeners with InsertReference the following information for a close-punch connection of t
1 Safety PrecautionsTopics Covered in this Chapter▪ Safety Guidelines▪ Cautionary Symbols▪ Safety Decals▪ Safety Sign-off SheetSafety GuidelinesSafety
Chapter 6: StiffenersClose-Punch 12–Bolt Pattern Laminated Stiffener to LaminatedBase Stiffener with an Inserts to a Base BootReference the following
Chapter 6: StiffenersClose-Punch 12–Bolt Pattern Laminated Stiffener to LaminatedBase Stiffener with an Inserts to a Base BootReference the following
Chapter 6: StiffenersAll information, illustrations, photos, and specifications in this manual are based on the latestinformation available at the tim
7 Roof AssemblyTopics Covered in this Chapter▪ Attaching the Inside Stiffener to the Top Outside Stiffener▪ Attaching the Eave Bracket to the Inside S
Chapter 7: Roof Assemblysheet and three-post sidewall sheets will have three inside stiffeners per sheet. The inside stiffeners areonly located at the
Chapter 7: Roof AssemblyFigure 7-2 Inside stiffener to the two-ring top stiffener for bins with an even number of ringsA Sidewall E Corrugation spacer
Chapter 7: Roof AssemblyAttaching the Eave Bracket to the Inside StiffenerEave brackets secure the roof rafter to the sidewall.Before You BeginInstall
Chapter 7: Roof AssemblyAttaching the Eave Angle to the Sidewall SheetThe eave angle secures each lower portion of the roof panels.What You Should Kno
Chapter 7: Roof AssemblyFigure 7-4 Exploded view of eave angle (four roof panels)A First eave angle (CTR-0187) H Eave bracket (CTR-0550)B 5/16 in. fla
Chapter 7: Roof AssemblyConnecting the Tension Member to the Eave BracketTension members connect to the eave brackets and are installed around the ins
Chapter 1: Safety PrecautionsFollow Safety Instructions — Read and Understand Manual• Carefully read all safety messages in this manual and safetysign
Chapter 7: Roof AssemblyAssembling a Laminated RafterLaminated rafters nest together to give additional strength and should be assembled before attach
Chapter 7: Roof AssemblyNOTE: Ensure that the flange of rafter clip (C) is facing up and seated below the flange of the rafterson one side and the fla
Chapter 7: Roof AssemblyEach assembled roof rafter receives two center collar rafter clips, identified as the left center collar rafterclip (D) and th
Chapter 7: Roof AssemblyAbout Temperature Cable Brackets and A-Frame AssembliesTemperature cable bracket installation locations must be considered pri
Chapter 7: Roof AssemblyFigure 7-9 A-frame installation sequence and temperature cable locations for 135 ft diameter binA12.3 ft radius location C 55.
Chapter 7: Roof AssemblyTable 7-1 A-frame installation sequence and temperature cable locations for 135 ft diameter bin (cont'd.)A-frame number R
Chapter 7: Roof AssemblyTable 7-1 A-frame installation sequence and temperature cable locations for 135 ft diameter bin (cont'd.)A-frame number R
Chapter 7: Roof AssemblyFigure 7-10 Installing a temperature cable bracketARoof rafterDLeft purlin clip (CTR-0315)B10 in. temperature cable bracket (C
Chapter 7: Roof AssemblyFigure 7-11 Supplier quick linkA PurlinC Supplier quick linkB Temperature cable bracket (CTR-0317)Attachment Locations of Purl
Chapter 7: Roof AssemblyFigure 7-12 Location of purlins for a 135 ft (41.1 m) diameter binsALocation of purlin number 1 (CTR-0554) G Location of purli
Chapter 1: Safety Precautions• Wear gloves to protect your hands from sharp edges onplastic or steel parts.Gloves• Wear steel-toed boots to help prote
Chapter 7: Roof AssemblyAssembling Purlin Number 11Purlin number 11 is located eleventh from the eave.Before You BeginPlace two roof rafters on the gr
Chapter 7: Roof AssemblyFigure 7-13 Purlin location 11ALeft-hand upper roof rafter (CTR-0548)F1/2 x 1-3/4 in. flange bolt (S-10252)B1/2 x 1-3/4 in. fl
Chapter 7: Roof AssemblyAssembling Purlin Number 10Purlin number 10 is located tenth from the eave.Before You BeginPlace two roof rafters on the groun
Chapter 7: Roof AssemblyFigure 7-14 Purlin location 10ALeft-hand upper roof rafter (CTR-0548)F1/2 x 1-3/4 in. flange bolt (S-10252)B1/2 x 1-3/4 in. fl
Chapter 7: Roof AssemblyThe A-frame assembly consists of two roof rafters identified as the left-hand roof rafter (A) and the right-hand roof rafter (
Chapter 7: Roof AssemblyFigure 7-15 Purlin location 9A Left-hand upper roof rafter (CTR-0548) H Purlin (CTR-0562)B1/2 x 1-3/4 in. flange bolt (S-10252
Chapter 7: Roof AssemblyAssembling Purlin Number 8Purlin number 8 is located eighth from the eave.Before You BeginPlace two roof rafters on the ground
Chapter 7: Roof AssemblyFigure 7-16 Purlin location 8A Left-hand upper roof rafter (CTR-0548) H Purlin (CTR-0561)B1/2 x 1-3/4 in. flange bolt (S-10252
Chapter 7: Roof AssemblyAssembling Purlin Number 7Purlin number 7 is located seventh from the eave.Before You BeginPlace two roof rafters on the groun
Chapter 7: Roof AssemblyFigure 7-17 Purlin location 7A Left-hand lower roof rafter (CTR-0549 andCTR-0635)H Purlin (CTR-0560)B1/2 x 1-3/4 in. flange bo
Commentaires sur ces manuels