Series 2000 Top Dry
Heater Control
Operator's Manual
PNEG-743
Date: 5-3-2006
PNEG-743
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - Operator's Manual

Series 2000 Top DryHeater ControlOperator's ManualPNEG-743Date: 5-3-2006PNEG-743

Page 2 - TABLE OF CONTENTS

11Series 2000 Top Dry Heater ControlQUICK START PROCEDURE1. Raise chutes.2. Fill drying chamber with grain.3. Turn toggle switch at fan/heater to &quo

Page 3 - Heater Operation

12Series 2000 Top Dry Heater ControlDRYING RATES/SHELLED CORNTop Dry Batch SeriesFan and heaterunit(s)10-12 H.P.36" fan3.5 millionBTU/HR10-16 H.P

Page 4 - SAFETY ALERT DECALS

13Series 2000 Top Dry Heater ControlDRYING RATES/SHELLED CORNTop Dry Batch SeriesFan and heaterunit(s)10-12 H.P.36" fan3.5 millionBTU/HR10-16 H.P

Page 5 - OPERATING PROCEDURE

14Series 2000 Top Dry Heater ControlFACTORY CONFIGURATIONConfiguration DipSwitches (Normally DoneAt Gsi)Top Dry remotedisplay at the bot-tom-dip switc

Page 6

15Series 2000 Top Dry Heater ControlERROR CONDITIONSsymbols will be flashing. If a limit switch error orone of the error numbers 1 through 8 occurs, t

Page 7

WARRANTYEXCEPT FOR THE ABOVE STATED EXPRESS LIMITED WARRANTIES, GSI MAKES NO WARRANTYOF ANY KIND, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT LIMITATION,

Page 8

This Equipment shall be installed in accordancewith the current installation codes and applicableregulations which should be carefully followed inall

Page 9

3Series 2000 Top Dry Heater ControlTABLE OF CONTENTSSafety ...

Page 10 - QUICK START PROCEDURE

4Series 2000 Top Dry Heater ControlGSI cannot warrant any roof damages due to excessivevacuum or internal pressure caused by fans or other airmoving s

Page 11 - DRYING RATES/SHELLED CORN

5Series 2000 Top Dry Heater ControlSAFETY ALERT DECALSThe GSI Group, Inc. recommendscontacting your local power company,and having a representative su

Page 12

6Series 2000 Top Dry Heater ControlOPERATING PROCEDUREThere are three possible configuration modes forthe Top Dry.1. Stand alone heater control. Maste

Page 13 - FACTORY CONFIGURATION

7Series 2000 Top Dry Heater ControlOPERATING PROCEDUREflashing. Use the up and down arrow switches toprogram the temperature.This first temperature s

Page 14 - 1 2 3 4 5 6

8Series 2000 Top Dry Heater ControlOPERATING PROCEDUREfrom right cursor flashing).When the grain temperaturegets to this point (or dry timertimes down

Page 15 - WARRANTY

9Series 2000 Top Dry Heater ControlOPERATING PROCEDURE1. At fan/heater turn toggleswitch to "ON" position. Ifusing a remote display orecono

Page 16

10Series 2000 Top Dry Heater ControlOPERATING PROCEDUREshut down, and then the fan will shutdown. If alimit opens or an error condition occurs during